6、数据处理及分析结果6.1排放概要客户连云港三威化学有限公司年份2017年车间/装置项目编号一车间LH17120603密封点情况:密封点总数:16312个可测密封点:16312个不可测密封点: 0个首次检测结果:共检测出泄漏点37处(阀门、法兰≥500ppm;泵密封、搅拌密封≥1000ppm)泄漏点情况见下表6-1:表6-1连云港三威化学有限公司泄漏点 序号密封点编号泄漏量(ppm)复测值(ppm)备注1SWCJF01-QLC02AF10989.1 160.5维修成功2SWCJF01-JBJSC03HF04509.0 5.5维修成功3SWCJF01-JBJSC03JF09588.6120.8维修成功4SWCJF01-ZLC03BF07648.75.5维修成功5SWCJF01-SJF04-F20777.919.4维修成功6SWCJQLC02#F05689.11.2维修成功7SWCJQLC02#F06888.71.5维修成功8SWCJF01QLC01#F01889.41.8维修成功9SWCJF01QLC01#F029804.11.5维修成功10SWCJF01QLC01#F039703.81.9维修成功11SWCJF01JBYF079808.031.7维修成功12SWCJF01JBYF13978.2160.2维修成功13SWCJZLC03#F10984.322.5维修成功14SWCJZLC03#F113490.140.8维修成功15SWCJZLC03#F12689.545.5维修成功16SWCJZLC03#F13788.118.6维修成功17SWGQ48F011978.580.4维修成功18SWGQ48F02507.955.6维修成功19SWGQ48F032988.75.8维修成功20SWGQ49F01982.860维修成功21SWGQ49F023988.610.5维修成功22SWGQ49F03979.9285维修成功23SWHCCJ-JBGZ02F03998.860.2维修成功24SWHCCJ-TRF01AF06509.46.6维修成功25SWHCCJ-TRF02DF01998.64.5维修成功26SWCJ03F03HHF06CF40998.620.8维修成功27SWCJF03HHF-05F01509.051.2维修成功28SWCJF03HHF-04F011393.810.9维修成功29SWCJF03HHF-04F021699.920.6维修成功30SWCJ-DHC01AF039539.731.5维修成功31SWCJ-DHC02AF037999.428.8维修成功32SWCJ-DHC03AF037124.319.5维修成功33SWCJ-DHC04AF039883.530.5维修成功34SWCJ-DHC05AF038119.640.8维修成功35SWCJ-DHC06AF039420.039.5维修成功36SWCJ-DHC07AF039564.745.5维修成功37SWCJ-DHC08AF039953.220.6维修成功2017年连云港三威化学有限公司检测概览如表6-2所示:
表6-2连云港三威化学有限公司检测概览
装置 检测工作量 泄漏情况 排放量(kg/年)
密封点分类 合计
其它 开口阀或开口管线 搅拌器(轴封) 法兰 泵(轴封) 连接件(螺纹连接) 阀门 取样连接系统 合计 数量 占比(%) 首测检测 维修检测
车间一 0 141 159 13333 297 0 2382 0 16312 37 0.22 2446.83 1649.83
合计 0 141 159 13333 297 0 2382 0 16312 37 0.22 2446.83 1649.83
根据*次检测数据库的汇总结果,利用相关方程法计算排放量,汇总如下:
通过*轮全面检测,该装置共有37个密封点发生泄漏,设备总体泄漏率为0.23%。经过核算,超过泄漏控制浓度的密封点所产生的排放量为817.62kg/年。
经过首轮尝试性维修后,泄漏点维修合格。维修后实现减排797.06kg/年,减排率达32.57%。
6、数据处理及分析结果6.1排放概要客户连云港三威化学有限公司年份2017年车间/装置项目编号一车间LH17120603密封点情况:密封点总数:16312个可测密封点:16312个不可测密封点: 0个首次检测结果:共检测出泄漏点37处(阀门、法兰≥500ppm;泵密封、搅拌密封≥1000ppm)泄漏点情况见下表6-1:表6-1连云港三威化学有限公司泄漏点 序号密封点编号泄漏量(ppm)复测值(ppm)备注1SWCJF01-QLC02AF10989.1 160.5维修成功2SWCJF01-JBJSC03HF04509.0 5.5维修成功3SWCJF01-JBJSC03JF09588.6120.8维修成功4SWCJF01-ZLC03BF07648.75.5维修成功5SWCJF01-SJF04-F20777.919.4维修成功6SWCJQLC02#F05689.11.2维修成功7SWCJQLC02#F06888.71.5维修成功8SWCJF01QLC01#F01889.41.8维修成功9SWCJF01QLC01#F029804.11.5维修成功10SWCJF01QLC01#F039703.81.9维修成功11SWCJF01JBYF079808.031.7维修成功12SWCJF01JBYF13978.2160.2维修成功13SWCJZLC03#F10984.322.5维修成功14SWCJZLC03#F113490.140.8维修成功15SWCJZLC03#F12689.545.5维修成功16SWCJZLC03#F13788.118.6维修成功17SWGQ48F011978.580.4维修成功18SWGQ48F02507.955.6维修成功19SWGQ48F032988.75.8维修成功20SWGQ49F01982.860维修成功21SWGQ49F023988.610.5维修成功22SWGQ49F03979.9285维修成功23SWHCCJ-JBGZ02F03998.860.2维修成功24SWHCCJ-TRF01AF06509.46.6维修成功25SWHCCJ-TRF02DF01998.64.5维修成功26SWCJ03F03HHF06CF40998.620.8维修成功27SWCJF03HHF-05F01509.051.2维修成功28SWCJF03HHF-04F011393.810.9维修成功29SWCJF03HHF-04F021699.920.6维修成功30SWCJ-DHC01AF039539.731.5维修成功31SWCJ-DHC02AF037999.428.8维修成功32SWCJ-DHC03AF037124.319.5维修成功33SWCJ-DHC04AF039883.530.5维修成功34SWCJ-DHC05AF038119.640.8维修成功35SWCJ-DHC06AF039420.039.5维修成功36SWCJ-DHC07AF039564.745.5维修成功37SWCJ-DHC08AF039953.220.6维修成功2017年连云港三威化学有限公司检测概览如表6-2所示:
表6-2连云港三威化学有限公司检测概览
装置 检测工作量 泄漏情况 排放量(kg/年)
密封点分类 合计
其它 开口阀或开口管线 搅拌器(轴封) 法兰 泵(轴封) 连接件(螺纹连接) 阀门 取样连接系统 合计 数量 占比(%) 首测检测 维修检测
车间一 0 141 159 13333 297 0 2382 0 16312 37 0.22 2446.83 1649.83
合计 0 141 159 13333 297 0 2382 0 16312 37 0.22 2446.83 1649.83
根据*次检测数据库的汇总结果,利用相关方程法计算排放量,汇总如下:
通过*轮全面检测,该装置共有37个密封点发生泄漏,设备总体泄漏率为0.23%。经过核算,超过泄漏控制浓度的密封点所产生的排放量为817.62kg/年。
经过首轮尝试性维修后,泄漏点维修合格。维修后实现减排797.06kg/年,减排率达32.57%。